Rehabilitation of a Pier Abutment Using a Custom Stress-Breaking Non-Rigid Connector in a Long-Span Fixed Partial Denture: A Clinical Case Report

Authors

  • Fr. Hrishikesh Ramkrishna Kadam VINAYAKA MISSION’S SANKARACHARIYAR DENTAL COLLEGE, VINAYAKA MISSION’S RESEARCH FOUNDATION-DU Author
  • Dr.Sunantha Selvaraj VINAYAKA MISSION'S SANKARACHARIYAR DENTAL COLLEGE. VINAYAKA MISSION'S RESEARCH FOUNDATION-DU Author
  • Dr. G. Rajkumar, VINAYAKA MISSION’S SANKARACHARIYAR DENTAL COLLEGE, VINAYAKA MISSION’S RESEARCH FOUNDATION-DU Author
  • Dr. Bhuvanesh Kumar D. V VINAYAKA MISSION’S SANKARACHARIYAR DENTAL COLLEGE, VINAYAKA MISSION’S RESEARCH FOUNDATION-DU Author

DOI:

https://doi.org/10.55995/qdk6qg31

Keywords:

Pier Abutment,, Non-rigid Connector,, Fixed Partial Denture, Key-keyway Connector, Stress Breaker

Abstract

Background:

Rehabilitating long-span partially edentulous arches with pier abutments in fixed prosthodontics is biomechanically challenging. Rigid connectors can concentrate stresses, causing retainer debonding, porcelain fracture, and prosthesis failure due to abutment teeth mobility. Limiting prosthesis component mobility and stress transmission with a non-rigid connector reduces stress. This paper describes clinical rehabilitation of a maxillary pier abutment using a custom key-keyway non-rigid connector in a metal-ceramic fixed partial denture.

Case presentation:

A 63-year-old woman came with missing teeth and had problems with mastication. Missing teeth 14, 16, 25, 26, and 27 and pier abutment tooth 15 were clinically present. A custom key–keyway non-rigid connector on the mesial pier abutment was planned for a five-unit porcelain-fused-to-metal fixed partial denture from teeth 13 to 17. A six-unit fixed partial denture from teeth 23–28 followed. Prostheses used DMLS and Type I glass ionomer luting cement. Outcome: Prostheses had good marginal adaptation, passive adjustment, functional occlusion, and esthetics. At 1 week, 1 month, and 4 months, we found stable occlusion, healthy periodontal tissues, no retainer loosening, connector failure, or ceramic fracture. Patient mastication and satisfaction improved.

Clinical Importance:

A custom key-keyway connector on a pier abutment reduces biomechanical stress. Clinical performance of long-span fixed partial dentures improves.

Author Biographies

  • Fr. Hrishikesh Ramkrishna Kadam, VINAYAKA MISSION’S SANKARACHARIYAR DENTAL COLLEGE, VINAYAKA MISSION’S RESEARCH FOUNDATION-DU

    1.     DR. HRISHIKESH RAMKRISHNA KADAM

    POSTGRADUATE STUDENT,

    DEPT OF PROSTHODONTICS AND CROWN &   BRIDGE,

    VINAYAKA MISSION’S SANKARACHARIYAR DENTAL COLLEGE,

    VINAYAKA MISSION’S RESEARCH FOUNDATION-DU

    SALEM, 636308

    TAMILNADU, INDIA.

    E-mail: hrishikeshkadam2898@gmail.com

    Contact no.- 8855000003.

    Orcid ID: 0009-0002-0768-2254

  • Dr.Sunantha Selvaraj, VINAYAKA MISSION'S SANKARACHARIYAR DENTAL COLLEGE. VINAYAKA MISSION'S RESEARCH FOUNDATION-DU

    1.     DR. SUNANTHA SELVARAJ, MDS,

    PROFESSOR,

    DEPT OF PROSTHODONTICS AND CROWN & BRIDGE,

    VINAYAKA MISSION’S SANKARACHARIYAR DENTAL COLLEGE,

    VINAYAKA MISSION’S RESEARCH FOUNDATION-DU

    SALEM,

    TAMIL NADU, INDIA.

    E-mail: drsunujai@yahoo.co.in

    Contact no.- 9994066144.

    Orcid ID: 0000-0001-6373-0084

  • Dr. G. Rajkumar,, VINAYAKA MISSION’S SANKARACHARIYAR DENTAL COLLEGE, VINAYAKA MISSION’S RESEARCH FOUNDATION-DU

    1.     DR. G. RAJKUMAR, MDS,

    PROFESSOR,

    DEPT OF PROSTHODONTICS AND CROWN & BRIDGE

    VINAYAKA MISSION’S SANKARACHARIYAR DENTAL COLLEGE,

    VINAYAKA MISSION’S RESEARCH FOUNDATION-DU

    SALEM, 636308

    TAMIL NADU, INDIA.

    E-mail: drrajkumar@vmsdc.edu.in

    Contact no.- 9443285888

    Orcid ID: 0000-0002-1670-1106

  • Dr. Bhuvanesh Kumar D. V, VINAYAKA MISSION’S SANKARACHARIYAR DENTAL COLLEGE, VINAYAKA MISSION’S RESEARCH FOUNDATION-DU

    1.     DR. BHUVANESH KUMAR D. V., MDS,

    ASSOCIATE PROFESSOR,

    DEPT OF PROSTHODONTICS AND CROWN & BRIDGE

    VINAYAKA MISSION’S SANKARACHARIYAR DENTAL COLLEGE,

    VINAYAKA MISSION’S RESEARCH FOUNDATION-DU

    SALEM, 636308

    TAMIL NADU, INDIA.

    E-mail: bhuvanesh4668@gmail.com

    Contact no.- 9944422297

    Orcid ID: 0000-0003-1733-3066

References

Reference

1. Shillingburg HT Jr, Hobo S, Whitsett LD, Jacobi R, Brackett SE. Fundamentals of fixed prosthodontics. 4th ed. Chicago (IL): Quintessence Publishing Co; 2012.

2. Rosenstiel SF, Land MF, Fujimoto J. Contemporary fixed prosthodontics. 6th ed. St. Louis (MO): Elsevier; 2022.

3. Grossmann Y, Pasciuta M, Finger IM. A novel design for a non-rigid connector in fixed partial dentures with pier abutments. J Prosthet Dent. 2006;95(3):241-6.

4. Oruc MS, Tulunoglu IF. Stress analysis of the effects of non-rigid connectors in fixed partial dentures with pier abutments. J Prosthet Dent. 2008;99(3):185-92.

5. Karl M, Taylor TD. Effect of material selection and connector design on the biomechanics of fixed dental prostheses. J Prosthodont. 2020;29(Suppl 1):S18-S26.

6. Sharma V, Meena KK, Gurjar BS, Nagar R. Pier abutment: Bridge the gap with non-rigid connector—A clinical case report. Acta Marisiensis Ser Med. 2022;68(2):68-71.

7. Akulwar R, More A, Nimonkar S, et al. Non-rigid connector for managing pier abutment in fixed partial denture: A case report. J Clin Diagn Res. 2014;8(7):ZD25-ZD27.

8. Yadav S, Kaur SP, Gaur V, Dabas N, Yadav B. Non-rigid connector for management of a pier abutment in fixed dental prosthesis. Indian J Health Sci Care. 2016;3(2):100-3.

9. Rathee M, Divakar S, Jain P, Singh S, Chahal S, Tomar SS. Digitally designed fixed dental prosthesis with stress-breaking effect using non-rigid connector for pier abutment: A case report. Acta Marisiensis Ser Med. 2022;68(4):199-202.

10. Revilla-León M, Özcan M. Additive manufacturing technologies used for processing polymers and metals in dentistry. J Prosthodont. 2019;28(2):146-58.

Downloads

Published

2026-04-28

Issue

Section

Case Reports

How to Cite

Rehabilitation of a Pier Abutment Using a Custom Stress-Breaking Non-Rigid Connector in a Long-Span Fixed Partial Denture: A Clinical Case Report. (2026). Journal of Clinical Prosthodontics and Implantology, 8(1), 23-27. https://doi.org/10.55995/qdk6qg31